Symmetrical Pair Cables For Communications Horizontal Floor Category 3 Product
Applications:
10Base-T
Characteristics:
Physical/Electrical characteristics |
|
|
|
|
|
Differential Phase Delay(Max) | 45ns/100m | Impedance | 4-16MHz 100±15Ω |
|
|
Mutual capacitance(Max) | 5. 6nF/100m | D. C Resistance(Max) | 9. 5Ω/100m at 20℃; |
|
|
Dielectric Strength Between Conductors(Min) | 2.5kV/2s | Permitted Bend Radius | No less than eight times the cable diameter |
|
|
Transmission Performance |
|
|
|
|
|
Frequency (MHz) | Attenuation (Max) (dB/100m) | NEXT(Min) (dB/100m) | ELFEXT(Min) (dB/100m) | RL (Min) (dB) | Phase Velocity (Min) (m. /s) |
4 | 5.6 | 32.3 | 27 | 12 | 0.604c |
8 | 8.5 | 27.8 | 20.9 | 12 | 0.610c |
10 | 9.7 | 26.3 | 19 | 12 | 0.612c |
16 | 13.1 | 23.2 | 14.9 | 10 | 0.614c |
Operating Temperature:-20℃~﹢60℃
Indoor Symmetrical Pair Cables For Digital Communications Horizontal Floor Wiring-UTP Category 3
UTP CAT3(HSYV3)
Product Structure:

Product Description:
UTP CAT3 HSYV3 (Category 3, PE Insulation, PVC sheath)
Standards:
YD/T 1019-2013 ISO/IEC11801, ANSI/TIA/EIA-568-C, UL444(Apply to Indoor data cable), IEC61156
Structure Parameters
Type | Wire Gauge | Logarithm | Diameter(mm) |
HSYV3 | 26AWG | 25 | 9.1 |